PEOPLE TAKING NO CARE OF DISPOSAL OF SULLAGE AND THE ADMINISTRATION FAILED TO FOLLOW CLEAN INDIA MOVEMENT OF THE GOVERNMENT OF INDIA, WHERE SUITABLE INSTRUCTIONS SHOULD BE ISSUED TO MAINTAIN CLEAN SURROUNDING BY EVERY CITIZEN OF SOCIETY AND THE AREA
Sewer lines are not maintained properly and sewer crossings are passed near to the buildings, even though all sewers should be away from the external walls of a building at least 1.20 metre from the end of building and it should not be passed under the building. If must, surround the (glazed ware) pipe with 150 mm of concrete or lay in the cast iron pipes and provide excesses at each end immediately outside the building. No branches should be connected to the portion of the drain under the building. Where pipes are passed on a bridge where vibrations occur, cast iron pipes with special couplings, rather than standard lead joints, should be used to avoid leakage. No bends whatever should be permitted in sewers except at man holes. Where a change of direction can not be avoided and this exceeds 45degree, access should normally be provided at the bends or junctions. The use of quarter bends (90degree) should be avoided, except at the foot of the bent pipes. All junctions should be oblique, and the contained angle be not more than 45 degree. Junctions made at 45 degree are called Y junctions and junctions formed at a smaller angle than 45 degree are called V junctions and are used to connect a very oblique branch drain with a principal drain. When a junction is fixed on the line of a drain, care should be taken to give it a tilt to the gradient of the incoming branch drain for which it is provided, and the oblique arm should be packed up with fine concrete to keep it in position. It is particularly mentioned here that the present set up of vision new India should be followed under the provision made for appropriate access to the guidelines related to drainage and sewerage, required to be maintained by separate systems, where either it is necessary to have a soak pit and treatment works for sludge purification under provision for the small units or it is essential to follow a combined system suitable for the town designs however in case of separate system for the sewerage it is considered most suitable for the individual house discharged into the soil sewers through septic tank and the soak pit required to be maintained 150 metre away from the house/buildings, so that it may not create nuisance because of the foil smells and it is too necessary to depend upon the accurate method of treatment to be adopted and require very careful considerations , as such a soak pit should not be less than 30 mt away from a well or any source of water supply, but people are taking no care of the design parameters and considerations and creating problems to the neighbourers and society and circle where the department of administration failing to resolve the redressal of grievances under Cr PC -133 and no punishment issued to the culprits against decision making of the department of police is a matter of concern :-- Er Fateh Chand Guleria, Director RTI welfare Association registered number HPCD, 3552 , Bilaspur Himachal Pradesh phone number 9459334377
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment